Vision Automation

Unitronics logo

Vision130

Vision130

Palm-size, powerful PLC with built-in black & white LCD 1.3″ graphic display, keypad & onboard I/O configurations, expands up to 256 I/Os.

Vision130 front

33-Series

Vision130-J front

J-Series

Vision130 side

Side

Vision130 back

Back

Click on an image to view a larger version; use your browser's "Back" button to return to this page.

More Info
33-Series

More Info
(J-Series)


Vision130 Overview

+PLC

  • I/O options include high-speed, temperature and weight measurement
  • Auto-tune PID, up to 24 independent loops
  • Recipe programs and data logging via Data Tables
  • Micro SD card – log, backup, clone and more
  • Date and time-based control

+HMI

  • 1024 user-designed screens
  • 400 images per application
  • HMI graphs and Trends
  • Built-in alarm screens
  • Text String Library – easy localization
  • Memory and communication monitoring via HMI – No PC needed

+Communication

  • TCP/IP via Ethernet
  • Web server: Use built-in HTML pages or design complex pages to view and edit PLC data via the Internet
  • Send e-mail function
  • SMS messaging
  • GPRS/GSM
  • Remote Access utilities
  • MODBUS protocol support
  • BACnet, M-bus – via 3rd-party converter
  • CANbus: CANopen, UniCAN, J1939 and more
  • DF1 Slave
  • SNMP agent V1
  • FB Protocol Utility: enables serial or TCP/IP communications with 3rd-party device; barcode readers, frequency converters, etc
  • Ports: supplied with 1 RS232/RS485; 2 ports may be added: 1 Serial/Ethernet/Profibus and 1 CANbus

+I/O

  • I/O options include digital, analog, high-speed, temperature and weight measurement. See tables below:
    • Vision130™ models – Onboard I/Os
    • I/O Expansion Modules

Vision130 Details

+I/O Expansion

Local or Remote I/Os may be added via expansion port or via CANbus. Expand up to 256 I/Os — see table below I/O Expansion Modules.

Notes:

  1. In some models certain inputs are adaptable via wiring and software settings, and can function as digital,high-speed, analog, and in certain models as TC or PT100.
    Adapting requires input pins. This reduces the number of digital inputs. Pin requirements:
    • Each high-speed requires 1 or 2 pins according to high-speed mode.
    • Each analog input requires 1 pin.
    • Each TC requires 2 pins per TC input
    • The first PT input requires 3 pins, and two additional pins for each additional PT input.
    Example: V130-33-RA22 offers 12 digital inputs. Implementing 2 TC inputs requires 4 pins, leaving 8 pins free. Implementing 2 PT inputs uses 5 input pins.
  2. The total number of digital inputs listed includes high-speed and adaptable inputs.
  3. The total number of digital outputs listed includes high-speed outputs.

+Program

Application Memory: Application Logic: 512K • Images: 256K • Fonts: 128K

Scan Time: 20µ sec per 1K of typical application

Memory Operands: 4096 coils, 2048 registers, 256 long integers (32-bit), 64 double words (32-bit unsigned), 24 floats, 192 timers (32-bit), 24 counters.
Additional non-retainable operands: 1024 X-bits, 512 X-integers, 256 X-long integers, 64 X-double words

Data Tables: 120K dynamic RAM data (recipe parameters, datalogs, etc.), up to 256K fixed data

SD Card (Micro): Store data logs, Alarm History, Data Tables, Trend data, export to Excel • Back up Ladder, HMI and OS, clone PLCs

Enhanced Features: Trends: graph any value and display on HMI • Built-in Alarm management system• String Library: instantly switch HMI language

+Operator Panel

Type and colors: Graphic STN LCD, white LED backlight

Display: Resolution: 128 x 64 pixels • Size: 2.4"

Keys: 20, including 10 user labeled keys (slide kit sold separately)

+General

Power Supply: 24VDC, except for V130-33-B1, which is 12/24VDC

Battery: 7 years typical at 25°C, battery back-up for all memory sections and RTC

Clock: Real-time clock functions (date and time)

Environment: IP66/IP65/NEMA4X (when panel mounted)

Standard: CE, UL Many of our products are also UL Class 1 Div 2 and GOST certified - please contact Unitronics

Vision130 Models - Onboard I/O

Tip: this table is best viewed on a wider screen such as a laptop or desktop PC

+Vision130 Models - Onboard I/O

Inputs 1 Outputs  
Article Summary Digital 2 HSC/Shaft-encoder 4 Analog Temperature
Measurement
Transistor 3 PWM/HSO 3 Relay Analog Operating
Voltage
V130-J-B1
V130-33-B1
No onboard I/OsNoneNoneNoneNoneNoneNoneNoneNone12/24VDC
V130-J-TR20
V130-33-TR20
10 Digital,
2 D/A Inputs1
6 Relay Outputs
2 High-speed Transistor Outputs
123
200kHz,
32-bit
2
0-10V,
0-20mA,
4-20mA
10-bit
None2 npn2
(2 PTO)
200 kHz max
6None24VDC
V130-J-R34
V130-33-R34
20 Digital,
2 D/A Inputs1
12 Relay Outputs
223
30kHz,
32-bit
2
0-10V,
0-20mA,
4-20mA
10-bit
NoneNoneNone12None24VDC
V130-J-TR34
V130-33-TR34
20 Digital,
2 D/A Inputs1
8 Relay,
4 High-speed Transistor Outputs
223
200kHz,
32-bit
2
0-10V,
0-20mA,
4-20mA
10-bit
None4 npn4
(3 PTO)
200 kHz max
8None24VDC
V130-J-TR6
V130-33-TR6
6 Digital,
2 D/A1,
4 Analog Input,
6 Relay Outputs,
2 High-speed Transistor Outputs
81
200kHz,
32-bit
2
0-10V,
0-20mA,
4-20mA
and 4
0-20mA,
4-20mA
10-bit
None2 npn2 (2 PTO)
200 kHz max
6None24VDC
V130-J-RA22
V130-33-RA22
8 Digital,
2 D/A,
2 TC / PT100 / Digital1 Inputs
8 Relay,
2 Analog Outputs
121
30kHz,
32-bit
2
0-10V,
0-20mA,
4-20mA
14-bit
2 Thermocouple, PT100NoneNone82
0-10V,
4 -20mA
12-bit
24VDC
V130-J-TRA22
V130-33-TRA22
8 Digital,
2 D/A,
2 PT100 / TC / Digital1 Inputs,
4 Relay,
2 Analog,
4 High-Speed Transistor Outputs
121
200kHz,
32-bit
2
0-10V,
0-20mA,
4-20mA
14-bit
2
Thermocouple, PT100
4 npn4
(2 PTO)
200 kHz max
42
0-10V,
4 -20mA
12-bit
24VDC
V130-J-T2
V130-33-T2
10 Digital,
2 D/A Inputs1
12 Transistor Outputs
123
30kHz,
32-bit
2
0-10V,
0-20mA,
4-20mA
10-bit
None12 pnp7 0,5KHzNoneNone24VDC
V130-J-T38
V130-33-T38
20 Digital,
2 D/A Inputs1,
16 Transistor Outputs
222
30kHz,
32-bit
2
0-10V,
0-20mA,
4-20mA
10-bit
None16 pnp7
0.5kHz
NoneNone24VDC
V130-J-TA24
V130-33-TA24
8 Digital,
2 D/A,
2 TC / PT100 / Digital1 Inputs,
10 Transistor,
2 Analog Outputs
121
30kHz,
32-bit
2
0-10V,
0-20mA,
4-20mA
14-bit
2 Thermocouple,
PT100
10 pnp5
0.5kHz
None2
0-10V,
4 -20mA
12-bit
24VDC

Notes:

  1. In some models certain inputs are adaptable via wiring and software settings, and can function as digital, high-speed, analog, and in certain models as TC or PT100.
    Adapting requires input pins. This reduces the number of digital inputs. Pin requirements:
    • Each high-speed requires 1 or 2 pins according to high-speed mode.
    • Each analog input requires 1 pin.
    • Each TC requires 2 pins per TC input
    • The first PT input requires 3 pins, and two additional pins for each additional PT input.
      Example: V130-33-RA22 offers 12 digital inputs. Implementing 2 TC inputs requires 4 pins, leaving 8 pins free. Implementing 2 PT inputs uses 5 input pins..
  2. The total number of digital inputs listed includes high-speed and adaptable inputs.
  3. The total number of digital outputs listed includes high-speed outputs.

I/O Expansion Modules

Tip: this table is best viewed on a wider screen such as a laptop or desktop PC

+I/O Expansion Modules

Inputs Outputs  
  Expansion Modules Digital 5 HSC/Shaft-encoder 5 Analog Temperature
Measurement
Weight
Measurement
Transistor 6 PWM/HSO 6 Relay Analog Operating
Voltage
Digital IO-DI8-TO88 pnp/npn1
5kHz 16-bit
NoneNoneNone8 pnpNoneNoneNone24VDC 9
IO-DI8-RO48 pnp/npn1
5kHz 16-bit
NoneNoneNoneNoneNone4None24VDC 9
IO-DI8-RO88 pnp/npn1
5kHz 16-bit
NoneNoneNoneNoneNone8None24VDC 9
EX90-DI8-RO8 38 pnp1
5kHz 16-bit
NoneNoneNoneNoneNone8None24VDC 9
IO-DI1616 pnp/npn1
5kHz 16-bit
NoneNoneNoneNoneNoneNoneNone24VDC 9
IO-TO16NoneNoneNoneNoneNone16 pnpNoneNoneNone24VDC 9
IO-RO8NoneNoneNoneNoneNoneNoneNone8None24VDC 9
IO-RO16NoneNoneNoneNoneNoneNoneNone16None24VDC 9
IO-DI8ACH8 ACNoneNoneNoneNoneNoneNoneNoneNone110/220 VAC
 
Inputs Outputs  
  Expansion Modules Digital 5 HSC/Shaft-encoder 5 Analog Temperature
Measurement
Weight
Measurement
Transistor 6 PWM/HSO 6 Relay Analog Operating
Voltage
Analog, Temperature and Weight/Strain Measurements IO-AI4-AO2NoneNone4
0-10V,
0-20mA,
4-20mA
12-bit
NoneNoneNoneNoneNone2
±10V
12-bit+sign,
0-20mA,
4-20mA
12-bit
24VDC
IO-PT400NoneNoneNone4
PT100 / NI100 / NI120
NoneNoneNoneNoneNoneNot relevant
IO-PT4KNoneNoneNone4
PT1000 / NI1000
NoneNoneNoneNoneNoneNot relevant
IO-AO6XNoneNoneNoneNoneNoneNoneNoneNone6 (Isolated)
0-10V,
0-20mA,
4-20mA
12-bit
24VDC
IO-LC11 pnpNoneNoneNone1
Loadcell / Strain gauge
2 pnpNoneNoneNone24VDC
IO-LC31 pnpNoneNoneNone3
Loadcell / Strain gauge
2 pnpNoneNoneNone24VDC
IO-ATC8NoneNone8 Thermocouple, 0-10V,
0-20mA, 4-20mA 14-bit
NoneNoneNoneNoneNoneNot relevant
IO-AI8NoneNone8
0-10V,
0-20mA,
4-20mA
14-bit
NoneNoneNoneNoneNoneNoneNot relevant
 
Inputs Outputs  
  Expansion Modules Digital 5 HSC/Shaft-encoder 5 Analog Temperature
Measurement
Weight
Measurement
Transistor 6 PWM/HSO 6 Relay Analog Operating
Voltage
XL Digital / Analog IO-D16A3-RO1616
pnp/npn
2
30kHz
16/32-bit 8
3
0-20mA,
4-20mA
10-bit
NoneNoneNoneNone16None24VDC
IO-D16A3-TO1616
pnp/npn
1
30kHz
16/32-bit 8
3
0-20mA,
4-20mA
10-bit
NoneNone15 pnp,
1 pnp/npn
1
pnp 0.5kHz
npn 50kHz
NoneNone24VDC
EX-D16A3-RO8 716
pnp/npn
2
30kHz
16/32-bit 8 8
3
0-20mA,
4-20mA
10-bit
NoneNoneNoneNone8none24VDC
EX-D16A3-TO16 716 pnp/npn1
30kHz
16/32-bit 8
3
0-20mA,
4-20mA
10-bit
NoneNone15 pnp
1 pnp/npn
1
pnp 0.5kHz
npn 50kHz
NoneNone24VDC
 
Inputs Outputs  
  Expansion Modules Digital 5 HSC/Shaft-encoder 5 Analog Temperature
Measurement
Weight
Measurement
Transistor 6 PWM/HSO 6 Relay Analog Operating
Voltage
High-speed Remote I/O Module EXF-RC15 2,49 pnp/npn3
200kHz
32-bit
NoneNoneNone4 npn4
(up to 3 PTO)
2None24VDC
 

Notes:

  1. Number of supported I/Os and I/O modules varies according to module
  2. The EXF-RC15 functions as a node in a Vision UniCAN network and connects to the Vision controller via CANbus and programmed in VisiLogic. The EXF-RC15 cannot be extended as regular I/O unit.
  3. The EX90 is housed in an open casing. Only one EX90 can be connected per PLC, as a single expansion module; Expansion adapter not required.
  4. Supported by Vision series. Not supported by M91 series.
  5. The total number of digital inputs listed includes high-speed inputs.. Example: the IO-D16A3-TO16 offers a total of 16 pnp/npn inputs. You can configure I4 as a HSC and I5 as a Counter reset; this reduces the available number of digital inputs to 14.
  6. The total number of digital outputs listed includes high-speed outputs. Example: the IO-D16A3-TO16 offers a total of 16 transistor outputs. You can configure 1 to High-speed output, reducing the number of available digital outputs to 15.
  7. Functions as local adapter. Can support up to 7 I/O modules
  8. 16-bit or 32-bit, depending on the PLC
  9. Also available as 12VDC – contact us for part number

Visilogic™ Software for Vision130™

All-in-One programming environment. Simple, fast development for both Ladder and HMI applications.

Information and download

Document Downloads

Tip: to save these files to your PC you may need to right-click and select "Save as..."

+Installation Guides

DownloadV130-33-B1/ V130-J-B1
DownloadV130-33-TR20/ V130-J-TR20
DownloadV130-33-R34/ V130-J-R34
DownloadV130-33-TR6/ V130-J-TR6
DownloadV130-33-RA22/ V130-J-RA22
DownloadV130-33-RA22/ V130-J-TRA22
DownloadV130-33-T2/ V130-J-T2
DownloadV130-33-T38/ V130-J-T38
DownloadV130-33-TA24/ V130-J-TA24
DownloadV130-33-TR34/ V130-J-TR34

+Technical Specifications

DownloadV130-33-B1/ V130-J-B1
DownloadV130-33-TR20/ V130-J-TR20
DownloadV130-33-R34/ V130-J-R34
DownloadV130-33-TR6/ V130-J-TR6
DownloadV130-33-RA22/ V130-J-RA22
DownloadV130-33-RA22/ V130-J-TRA22
DownloadV130-33-T2/ V130-J-T2
DownloadV130-33-T38/ V130-J-T38
DownloadV130-33-TA24/ V130-J-TA24
DownloadV130-33-TR34/ V130-J-TR34

+2D Drawings

Download2D Drawing

+3D Drawings

DownloadV130
DownloadV130-J

What does Vision130 look like?

Watch the Vision130 overview video.

Need more information?

Fill in your details and we will reply shortly.
This query places you under no obligation.